Lo Carbon Sentinel Kinetic BH Heat Recovery Unit


Vent Axia 443319 Lo-Carbon Sentinel Kinetic BH
Whole house heat recovery system with summer bypass and humidistat

Vent Axia's Sentinel Kinetic is the UK's most popular MVHR range with a host of features to suit all installations and a build quality that offers years of trouble free, reliable service.

  • Heat Recovery Efficiency: 90%
  • Suitable for houses up to 150 m2
  • Airflow Max: 280m3/hr
  • Airflow @100Pa: 245m3/hr
  • Dimensions WxHxD (mm): 550x550x285
  • Extra low energy use
  • Mechanical summer by-pass
  • Internal humidity sensor
  • Digital control
  • 5 Year warranty
  • Vertical or horizontal connections
  • Left or right-hand configuration
  • Details:

    • Integral Humidity sensor
      The integral humidity sensor increases speed in proportion to relative humidity levels, saving energy and reducing noise. The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet-room. Night time relative humidity setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature. Acoustically lined - low noise levels from only 20dB(A) @3m.
    • Summer Bypass and Anti Frost Protection
      An internal damper is activated when the outside temperature is less than the room temperature. The damper opens allowing cooler fresh air to bypass the Heat Recovery Cell and reduce the internal temperature towards the pre-set 'Comfort Temperature'. When the inside air temperature reaches the pre set 'Comfort temperature' the bypass damper closes.
      Anti-frost protection: In cold climates there is a possibility of frost building up on the intake side of the heat exchanger. In order to prevent damage, the Kinetic reduces supply flow while maintaining extract flow at temperatures below zero.
    • Purge setting
      The unit can be set to maximum flow (100%) by pressing and holding the Boost button on the unit itself or optional wireless controller for 5 seconds. Purge will continue for two hours unless cancelled by pressing the Boost button again.
    • Filtration
      2 x G4 with the option of a F7 pollen intake filter.
    • Controllability
      The Lo-Carbon Sentinel Kinetic models have 3 fully adjustable speeds and a purge setting (maximum flow). Provided with the unit is a digital controller that can be used to pre-set the speeds to any required airflow within the performance range. Boost can be achieved with almost any type of sensor or switch including momentary.

    Range Overview:

    Vent Axia's Sentinel Kinetic is the UK's most popular MVHR range, combining supply and extract ventilation in one unit. Stale and moist air is extracted from the kitchen, bathrooms and bedrooms through ducting and passed through a heat exchanger before being exhausted to the outside. Fresh incoming air is preheated via the integral heat exchanger which recovers up to 90% of the heat energy that would otherwise be wasted. The unit's energy saving Vent-Axia LoWatt DC motors further improve its efficiency and carbon reducing capabilities, with the Sentinel Kinetic boasting 0.72 w/l/s low SFP.

    In addition, heat recovery ventilation reduces excessive moisture in the air, combating condensation and subsequent mould growth, saving money on maintenance and decoration in the long and short-term. Home owners or tenants are further aided through better indoor air quality which has the duel health benefits of reducing microscopic fungal growth and eliminating the conditions in which house dust mites thrive, both of which are linked to allergic reactions and asthma.

    This lightweight and quiet-running unit is suitable for installation in kitchen cupboards. The system's exact ventilation rate can be set on the LCD display at low, normal or boost speeds to match the volume of the property. This operation is then further enhanced by a range of external, plug and play control and sensor options which can account for changes in humidity, air quality, PIR (Passive Infra Red), CO2 and temperature. In addition the operating temperature settings can be pre-programmed for automatic operation of the summer bypass, providing free summer cooling. Wireless control options are also available, allowing controls to be located in the most convenient position.

    An easily accessible heat recovery cube protected by two removable EU3 filters. Two Lo-Carbon Energy Saving EC DC fans ensure long life (typically over double the life of AC motors) and lowest possible energy use. Fully insulated construction with built in condensation drain. Vent-Axia Lo-Carbon Sentinel Kinetic meets the latest requirements of the Building Regulations Document F 2006 for wholehouse system ventilation.